{"title":"Electrical Wiring","description":null,"products":[{"product_id":"southwire-southwire®-romex®-brand-simpull®-nm-b-building-wire","title":"Southwire® Romex® Brand SIMpull® NM-B Building Wire 250'","description":"\u003cp\u003eNonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. Four Conductor Available With Two Neutrals. SIMpull® Jacket Designed for Easier Pulling.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eSouthwire® Romex® Brand SIMpull® NM-B (nonmetallic-sheathed) cable may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified in the National Electrical Code. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B cable is 600 volts.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Southwire","offers":[{"title":"250 ft.","offer_id":44519081509145,"sku":"233569","price":200.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-213433.jpg?v=1780323772"},{"product_id":"southwire-underground-feeder-wire","title":"Southwire Underground Feeder Cable Wire, 14\/2 Gauge - 250 Ft","description":"\u003cp\u003eUnderground Feeder and Branch Circuit Cable. 600 Volt. Copper Conductors. Sunlight, Moisture, and Fungus Resistant Overall PVC Jacket.\u003c\/p\u003e\n\u003cp\u003eSouthwire® copper UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2011 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.\u003c\/p\u003e","brand":"Southwire","offers":[{"title":"250 ft.","offer_id":44519082754329,"sku":"233965","price":149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-213428.jpg?v=1780323781"},{"product_id":"southwire-underground-feeder-cable-12-2-gauge-250-ft","title":"Southwire Underground Feeder Cable - 12\/2 Gauge - 250 Ft","description":"\u003cp\u003eUnderground Feeder and Branch Circuit Cable. 600 Volt. Copper Conductors. Sunlight, Moisture, and Fungus Resistant Overall PVC Jacket.\u003c\/p\u003e\n\u003cp\u003eSouthwire® copper UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2011 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Southwire","offers":[{"title":"250 ft.","offer_id":44519086883097,"sku":"234377","price":229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-213427.jpg?v=1780323795"},{"product_id":"southwire-underground-feeder-cable-10-2-gauge-250-ft","title":"Southwire Underground Feeder Cable - 10\/2 Gauge - 250 Ft","description":"\u003cp\u003eUnderground Feeder and Branch Circuit Cable. 600 Volt. Copper Conductors. Sunlight, Moisture, and Fungus Resistant Overall PVC Jacket.\u003c\/p\u003e\n\u003cp\u003eSouthwire® copper UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2011 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Southwire","offers":[{"title":"250 ft.","offer_id":44519104119065,"sku":"235598","price":399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-213425.jpg?v=1780323884"},{"product_id":"4-ft-10-4-srdt-black-round-dryer-cord","title":"4-Ft. 10\/4 SRDT Black Round Dryer Cord","description":"\u003cp\u003eMaster Electrician, 4', 10\/4 SRDT, Black Round Dryer Cord, Right Angle Male Plug, 30A, 125\/250V, NEMA 14-30, UL Listed.\u003c\/p\u003e","brand":"Master Electrician","offers":[{"title":"Default Title","offer_id":44524203966745,"sku":"536920","price":29.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-39858.jpg?v=1780323731"},{"product_id":"6-ft-6-2-8-2-srdt-black-round-range-cord","title":"6-Ft. 6\/2 \u0026 8\/2 SRDT Black Round Range Cord","description":"\u003cp\u003eMaster Electrician, 6', 6\/2 \u0026amp; 8\/2 SRDT, Black Round Range Cord, Right Angle Male Plug, 45A, 125\/250V, NEMA 14-50, UL Listed.\u003c\/p\u003e","brand":"Master Electrician","offers":[{"title":"6 ft.","offer_id":44524969918745,"sku":"577715","price":39.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-41132.jpg?v=1780323720"},{"product_id":"6-ft-10-4-srdt-black-round-dryer-cord","title":"6-Ft. 10\/4 SRDT Black Round Dryer Cord","description":"\u003cp\u003eMaster Electrician, 6', 10\/4 SRDT, Black Round Dryer Cord, Right Angle Male Plug, 30A, 125\/250V, NEMA 14-30, UL Listed.\u003c\/p\u003e","brand":"Master Electrician","offers":[{"title":"6 ft.","offer_id":44524970180889,"sku":"577756","price":36.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-41123.jpg?v=1781028410"},{"product_id":"halex-57699-oval-service-cable-cap-3-1-0-4-0","title":"Halex 57699 Oval Service Cable Cap ~ 3#1\/0-#4\/0","description":"","brand":"Halex","offers":[{"title":"Default Title","offer_id":45505835172121,"sku":"834390","price":21.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-302904.jpg?v=1780324096"},{"product_id":"copy-of-marmon-home-improvement-200-ft-4-1-soild-bare-copper-grounding-wire","title":"Marmon Home Improvement 200 ft. 4\/1 Soild Bare Copper Grounding Wire","description":"\u003cp\u003eFor use in overhead transmission and distribution applications. Also for use in grounding applications.\u003c\/p\u003e","brand":"Marmon Home Improvement","offers":[{"title":"200'","offer_id":45665729904921,"sku":"379875","price":3.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-329416.png?v=1781129783"},{"product_id":"cerrowire-cerromax-nonmetallic-sheathed-indoor-copper-building-cable","title":"CerroWire CerroMax™ Nonmetallic Sheathed Indoor Copper Building Cable","description":"\u003ch3 class=\"et_pb_toggle_title\"\u003eApplications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFor use primarily in residential wiring, including branch circuits for outlets, switches, etc.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMay be installed in both exposed and concealed work in normally dry locations. May be installed in air voids of masonry block or tile walls where these walls are not subject to excessive moisture or dampness. May be installed in locations with temperatures up to 90°C, but with the ampacity limited to that of 60°C conductors. Added Circuit: For use primarily in residential wiring for branch circuits supplying outlets located in bedrooms and other areas. Has two separated neutrals so one cable can be used to run two circuits when sharing of a neutral is not allowed.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBranch circuit wiring\u003c\/li\u003e\n\u003cli\u003eCeiling fans\u003c\/li\u003e\n\u003cli\u003eDry locations only\u003c\/li\u003e\n\u003cli\u003eReceptacles\u003c\/li\u003e\n\u003cli\u003eResidential\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"et_pb_toggle_title\"\u003eConductors\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSolid conductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSoft, uncoated copper per ASTM B3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStranded conductors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUncoated copper per ASTM B3 and ASTM B8\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"et_pb_toggle_title\"\u003eInsulation\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eColor-coded PVC (polyvinyl chloride) rated 90°C dry with nylon (polyamide) covering\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e(Where included, additional neutral will have a red stripe for identification.)\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"et_pb_toggle_title\"\u003eJacket\u003c\/h3\u003e\n\u003cp\u003ePVC (polyvinyl chloride) jacket applied over the complete assembly\u003c\/p\u003e\n\u003cp\u003e14-2 AWG: White jacket;  14-3 AWG: Light Blue\u003cbr\u003e12-2 AWG: Yellow jacket;  12-3 AWG: Purple\u003cbr\u003e10-2 AWG: Orange jacket; 10-3 AWG: Pink\u003cbr\u003e8 AWG: Black jacket\u003c\/p\u003e\n\u003cp\u003eCustom jacket colors available with minimum order quantities\u003c\/p\u003e\n\u003ch3 class=\"et_pb_toggle_title\"\u003eIndustry Standards\u003c\/h3\u003e\n\u003cp\u003eStandards:\u003cbr\u003eUL 719: E9810\u003cbr\u003eUL 83: E15119\u003cbr\u003eASTM B3\u003cbr\u003eASTM B8\u003c\/p\u003e\n\u003cp\u003e*It is the sole responsibility of the end user to determine suitability of this product for its intended end use and application.\u003c\/p\u003e\n\u003ch3 class=\"et_pb_toggle_title\"\u003eAssembly\u003c\/h3\u003e\n\u003cp\u003ePVC-jacketed cable with two-, three- or four-circuit conductors and an equipment grounding conductor. Intended for use in accordance with the National Electrical Code\u003csup\u003e®\u003c\/sup\u003e.\u003c\/p\u003e\n\u003cp\u003eTwo-conductor constructions have the insulated conductors laid parallel. The ground wire is wrapped with fire-retardant paper and laid parallel between the insulated conductors. The entire construction is wrapped with a paper separator before applying the jacket.\u003c\/p\u003e\n\u003cp\u003eThree (or more) conductor constructions have the insulated conductors twisted together or laid parallel to each other. Ground wire is wrapped with paper and twisted together or laid parallel to the insulated conductor.\u003c\/p\u003e\n\u003ch3 class=\"et_pb_toggle_title\"\u003eSurface Print\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSample: NM-B 14-2 W\/G CerroMax-I (UL)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e(Additional information may be included.)\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"et_pb_toggle_title\"\u003eColors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cimg\u003e\u003cspan\u003eWhite: 14\/2 \u003cspan class=\"small_caps\"\u003eawg\\\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNMB Light Blue: 14\/3 \u003cspan class=\"small_caps\"\u003eawg\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eYellow: 12\/2 \u003cspan class=\"small_caps\"\u003eawg\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNMB Purple: 12\/3 \u003cspan class=\"small_caps\"\u003eawg\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOrange: 10\/2 \u003cspan class=\"small_caps\"\u003eawg\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNMB Pink: 10\/3 \u003cspan class=\"small_caps\"\u003eawg\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eBlack: 4, 6, 8 \u003cspan class=\"small_caps\"\u003eawg\u003c\/span\u003e\u003c\/span\u003e\u003cimg\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Cerrowire","offers":[{"title":"12 ft. Yellow","offer_id":49467326562585,"sku":"169758","price":34.99,"currency_code":"USD","in_stock":true},{"title":"15' 10\/2","offer_id":52020412776729,"sku":"169760","price":77.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-374470.gif?v=1780324424"},{"product_id":"southwire-romex-brand-simpull-type-nm-b-cable-14-3","title":"Southwire Romex® Brand SIMpull® Type NM-B Cable 14-3","description":"\u003cp class=\"info-panel__description\"\u003eNonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. SIMpull® Jacket Designed for Easier Pulling.\u003c\/p\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eApplication\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cp\u003e\u003cspan\u003eSouthwire® Romex ® Brand SIMpull® NM-B (nonmetallic-sheathed) cable may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified in the National Electrical Code. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B cable is 600 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eStandards \u0026amp; References\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cp\u003eSouthwire Romex® Brand SIMpull® NM-B cable complies with the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eListed per UL Standard 719\u003c\/li\u003e\n\u003cli\u003eUL 83 (Conductor Construction)\u003c\/li\u003e\n\u003cli\u003eASTM B-3 and B-8\u003c\/li\u003e\n\u003cli\u003eFederal Specification A-A-59544\u003c\/li\u003e\n\u003cli\u003eNational Electrical Code, NFPA 70\u003c\/li\u003e\n\u003cli\u003eREACH\/RoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eConstruction\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cp\u003e\u003cspan\u003eSouthwire Romex® Brand SIMpull® NM-B cable is manufactured as 2, 3, or 4 conductor cable, with a bare ground wire. Copper conductors are annealed (soft)copper. Stranded conductors are compressed stranded. Conductor insulation is 90°C-rated polyvinyl chloride (PVC), nylon jacketed. Romex® Brand SIMpull® NM-B cable is designed for easier pulling, resulting in easier installation. The cable jacket is color-coded for quick size identification; White - 14 AWG, Yellow - 12 AWG, Orange - 10 AWG, and Black - 8 AWG and 6 AWG.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Southwire","offers":[{"title":"50'","offer_id":49503660146969,"sku":"853192","price":77.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-375509.jpg?v=1780324442"},{"product_id":"southwire-romex-brand-simpull-nm-b-cable-14-3-cu","title":"Southwire Romex® Brand SIMpull® NM-B Cable  14-3 CU","description":"\u003cp class=\"info-panel__description\"\u003eNonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. SIMpull® Jacket Designed for Easier Pulling.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSouthwire Romex® Brand SIMpull® NM-B cable is manufactured as 2, 3, or 4 conductor cable, with a bare ground wire. Copper conductors are annealed (soft)copper. Stranded conductors are compressed stranded. Conductor insulation is 90°C-rated polyvinyl chloride (PVC), nylon jacketed. Romex® Brand SIMpull® NM-B cable is designed for easier pulling, resulting in easier installation. The cable jacket is color-coded for quick size identification; White - 14 AWG, Yellow - 12 AWG, Orange - 10 AWG, and Black - 8 AWG and 6 AWG.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!----\u003e","brand":"Southwire Company","offers":[{"title":"25 ft.","offer_id":49530053230873,"sku":"853200","price":67.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-375331.jpg?v=1780324477"},{"product_id":"southwire-s-romex-brand-simpull-type-nm-b-cable-6-3-cu-nm-b-with-ground-50-ft-copy-1","title":"Southwire 12\/3 Solid Romex Type NM-B WG Non-Metallic Wire Coil Purple","description":"\u003cp\u003e\u003cspan\u003eWire residential indoor branch circuits for outlets, switches and other loads with Southwire Romex SIMpull Type NM-B Cable. Slik quik jacket allows for 50 percent reduction in pulling force for easier installation. May be run in air voids of masonry block or tile walls not subject to excessive moisture and dampness.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul id=\"product-features\"\u003e\n\u003cli class=\"product-text\"\u003eCoated in patented SIMpull Cable Jacket for easier pulling; stripping; and installation\u003c\/li\u003e\n\u003cli class=\"product-text\"\u003eRomex Type NM-B Copper Building Wire is commonly applied in residential building wiring as a branch circuit for switches and outlets\u003c\/li\u003e\n\u003cli class=\"product-text\"\u003eInstallation above ground and in dry locations only\u003c\/li\u003e\n\u003cli class=\"product-text\"\u003eThe voltage rating of the cable is 600 volts.\u003c\/li\u003e\n\u003cli class=\"product-text\"\u003eNM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Southwire","offers":[{"title":"25 ft Purple","offer_id":49712758620441,"sku":"853184","price":92.99,"currency_code":"USD","in_stock":true},{"title":"50 ft Purple","offer_id":51756866175257,"sku":"853176","price":134.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-375092.jpg?v=1780324542"},{"product_id":"copy-of-marmon-home-improvement-500-ft-12-gauge-white-stranded-copper-thhn-wire","title":"Marmon Home Improvement 500 ft. 12 Gauge White Stranded Copper THHN Wire","description":"\u003cp\u003eThermoplastic-insulated copper wire with a nylon covering. Sizes 8 AWG through 1000 kcmil feature Cerrowire SLiPWire® Technology for fast and easy pulling in conduit. This 90°C, 600 volt building wire is for use in residential, commercial and industrial applications. Intended for use in accordance with the National Electrical Code® in both wet and dry locations. Conductors 14 AWG through 1 AWG are marked VW-1 and 1\/0 AWG through 1000 kcmil are rated for use in cable tray. When used as appliance wire, 105°C dry rated.\u003c\/p\u003e","brand":"Marmon Home Improvement","offers":[{"title":"500' \/ White","offer_id":50246983254297,"sku":"548131","price":1.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-329456.jpg?v=1780324205"},{"product_id":"copy-of-marmon-home-improvement-500-ft-10-gauge-black-stranded-copper-thhn-wire","title":"Marmon Home Improvement 500 ft. 10 Gauge Black Stranded Copper THHN Wire","description":"\u003cp\u003eThermoplastic-insulated copper wire with a nylon covering. Sizes 8 AWG through 1000 kcmil feature Cerrowire SLiPWire® Technology for fast and easy pulling in conduit. This 90°C, 600 volt building wire is for use in residential, commercial and industrial applications. Intended for use in accordance with the National Electrical Code® in both wet and dry locations. Conductors 14 AWG through 1 AWG are marked VW-1 and 1\/0 AWG through 1000 kcmil are rated for use in cable tray. When used as appliance wire, 105°C dry rated.\u003c\/p\u003e","brand":"Marmon Home Improvement","offers":[{"title":"500' \/ Black","offer_id":50246983680281,"sku":"548156","price":1.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-329449.jpg?v=1780324208"},{"product_id":"copy-of-marmon-home-improvement-500-ft-12-gauge-green-stranded-copper-thhn-wire","title":"Marmon Home Improvement 500 ft. 12 Gauge Green Stranded Copper THHN Wire","description":"\u003cp\u003eThermoplastic-insulated copper wire with a nylon covering. Sizes 8 AWG through 1000 kcmil feature Cerrowire SLiPWire® Technology for fast and easy pulling in conduit. This 90°C, 600 volt building wire is for use in residential, commercial and industrial applications. Intended for use in accordance with the National Electrical Code® in both wet and dry locations. Conductors 14 AWG through 1 AWG are marked VW-1 and 1\/0 AWG through 1000 kcmil are rated for use in cable tray. When used as appliance wire, 105°C dry rated.\u003c\/p\u003e","brand":"Marmon Home Improvement","offers":[{"title":"500' \/ Green","offer_id":50246984106265,"sku":"746354","price":1.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-329452.jpg?v=1780324207"},{"product_id":"copy-of-marmon-home-improvement-500-ft-12-gauge-red-stranded-copper-thhn-wire","title":"Marmon Home Improvement 500 ft. 12 Gauge Red Stranded Copper THHN Wire","description":"\u003cp\u003eThermoplastic-insulated copper wire with a nylon covering. Sizes 8 AWG through 1000 kcmil feature Cerrowire SLiPWire® Technology for fast and easy pulling in conduit. This 90°C, 600 volt building wire is for use in residential, commercial and industrial applications. Intended for use in accordance with the National Electrical Code® in both wet and dry locations. Conductors 14 AWG through 1 AWG are marked VW-1 and 1\/0 AWG through 1000 kcmil are rated for use in cable tray. When used as appliance wire, 105°C dry rated.\u003c\/p\u003e","brand":"Marmon Home Improvement","offers":[{"title":"500' \/ Red","offer_id":50349424574745,"sku":"548149","price":1.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-329454.jpg?v=1780324205"},{"product_id":"southwire-romex-brand-simpull-type-nm-b-14-2-cu-nm-b-with-ground","title":"Southwire Romex® Brand SIMpull® Type NM-B 14-2 CU NM-B with Ground","description":"\u003ch4 class=\"tab-panel__heading\"\u003eApplication \u0026amp; Features\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eSouthwire Romex\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e Brand SIMpull\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e Type NM-B (nonmetallic-sheathed) cable may be used for both exposed and concealed work in dry locations as specified in the National Electrical Code®. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B cable is 600 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eConstruction\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cul\u003e\n\u003cli\u003eConductor: Bare copper per ASTM B3. Sizes #14 AWG - #10 AWG are solid. Sizes #8 AWG - #2 AWG are Class B compressed stranded per ASTM B8\u003c\/li\u003e\n\u003cli\u003eInsulation: All phases and neutral(s) are insulated with Polyvinyl Chloride (PVC) with Nylon Sheath 2\/C: Black, White 3\/C: Black, Red, White 4\/C: Black, Red, Blue, White\u003c\/li\u003e\n\u003cli\u003eGround: Solid soft drawn bare copper with kraft paper wrap\u003c\/li\u003e\n\u003cli\u003eBinder: Kraft paper\u003c\/li\u003e\n\u003cli\u003eJacket: Polyvinyl Chloride (PVC) jacket utilizing SIMpull Technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eStandards \u0026amp; References\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cul\u003e\n\u003cli\u003eASTM B3 Soft or Annealed Copper Wire\u003c\/li\u003e\n\u003cli\u003eASTM B8 Concentric-Lay-Stranded Copper Conductors\u003c\/li\u003e\n\u003cli\u003eUL 719 Nonmetallic-Sheathed Cables\u003c\/li\u003e\n\u003cli\u003eRoHS-2 (European Directive 2011\/65\/EU)\u003c\/li\u003e\n\u003cli\u003eFederal Specification A-A-59544\u003c\/li\u003e\n\u003cli\u003eNOM-063-SCFI Electrical Products – Conductors – Safety Requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Southwire","offers":[{"title":"25'","offer_id":50546660114713,"sku":"110437","price":39.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-439719.png?v=1780324421"},{"product_id":"southwire-s-romex-brand-simpull-type-nm-b-cable-6-3-cu-nm-b-with-ground-50-ft-copy","title":"Southwire Romex® Brand SIMpull® Type NM-B Cable 12-3","description":"\u003cp class=\"info-panel__description\"\u003eNonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. SIMpull® Jacket Designed for Easier Pulling.\u003c\/p\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eApplication\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cp\u003eSouthwire® Romex ® Brand SIMpull® NM-B (nonmetallic-sheathed) cable may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified in the National Electrical Code. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B cable is 600 volts.\u003c\/p\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eStandards \u0026amp; References\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cp\u003eSouthwire Romex® Brand SIMpull® NM-B cable complies with the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eListed per UL Standard 719\u003c\/li\u003e\n\u003cli\u003eUL 83 (Conductor Construction)\u003c\/li\u003e\n\u003cli\u003eASTM B-3 and B-8\u003c\/li\u003e\n\u003cli\u003eFederal Specification A-A-59544\u003c\/li\u003e\n\u003cli\u003eNational Electrical Code, NFPA 70\u003c\/li\u003e\n\u003cli\u003eREACH\/RoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eConstruction\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cp\u003eSouthwire Romex® Brand SIMpull® NM-B cable is manufactured as 2, 3, or 4 conductor cable, with a bare ground wire. Copper conductors are annealed (soft)copper. Stranded conductors are compressed stranded. Conductor insulation is 90°C-rated polyvinyl chloride (PVC), nylon jacketed. Romex® Brand SIMpull® NM-B cable is designed for easier pulling, resulting in easier installation. The cable jacket is color-coded for quick size identification; White - 14 AWG, Yellow - 12 AWG, Orange - 10 AWG, and Black - 8 AWG and 6 AWG.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Southwire","offers":[{"title":"100'","offer_id":50678675276057,"sku":"163436","price":169.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-369875.jpg?v=1780324458"},{"product_id":"southwire-14-2-cu-uf-b-with-groundd","title":"Southwire 14-2 CU UF-B with Ground","description":"\u003ch3 class=\"tab-panel__heading\"\u003eConstruction\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cul\u003e\n\u003cli\u003eConductor: Solid soft drawn bare copper per ASTM B3 or class B compressed stranded soft drawn bare copper per ASTM B8\u003c\/li\u003e\n\u003cli\u003eInsulation: All phases and neutral are insulated with Polyvinyl Chloride (PVC) with Nylon Sheath\u003c\/li\u003e\n\u003cli\u003eGround: Solid soft drawn bare copper\u003c\/li\u003e\n\u003cli\u003eJacket: Gray Polyvinyl Chloride (PVC) jacket. Sunlight, moisture and fungus resistant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eStandards \u0026amp; References\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cul\u003e\n\u003cli\u003eASTM B3 Soft or Annealed Copper Wire\u003c\/li\u003e\n\u003cli\u003eASTM B8 Concentric-Lay-Stranded Copper Conductors\u003c\/li\u003e\n\u003cli\u003eUL 493 Thermoplastic-Insulated Underground Feeder and Branch-Circuit Cables\u003c\/li\u003e\n\u003cli\u003eRoHS-2 (European Directive 2011\/65\/EU)\u003c\/li\u003e\n\u003cli\u003eNEC National Electrical Code NFPA 70\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eApplication \u0026amp; Features\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cp\u003e\u003cspan\u003eSouthwire® copper UF-B cable is generally used as a feeder to outside post lamps, pumps, and other loads or apparatuses fed from a distribution point in an existing building as specified in the National Electrical Code®. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Southwire","offers":[{"title":"50 ft","offer_id":50710290956569,"sku":"853135","price":62.99,"currency_code":"USD","in_stock":true},{"title":"100 ft","offer_id":50806955213081,"sku":"853127","price":97.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-444046.png?v=1780324552"},{"product_id":"southwire-12-sol-sd-cu-thhn-thwn-awm-white","title":"Southwire 12 SOL SD CU THHN-THWN-AWM","description":"\u003ch3 class=\"tab-panel__heading\"\u003eConstruction\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cul\u003e\n\u003cli\u003eConductor: Solid sizes #14 AWG - #10 AWG use soft drawn bare copper per ASTM B3. Stranded sizes #14 AWG - #10 AWG use a combination-unilay stranded soft drawn bare copper per ASTM B787.\u003c\/li\u003e\n\u003cli\u003eInsulation: Heat and moisture resistant PVC\u003c\/li\u003e\n\u003cli\u003eSheath: Nylon\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eStandards \u0026amp; References\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cul\u003e\n\u003cli\u003eASTM B3 Soft or Annealed Copper Wire\u003c\/li\u003e\n\u003cli\u003eASTM B787 19 Wire Combination Unilay-Stranded Copper Conductors\u003c\/li\u003e\n\u003cli\u003eUL 83 Thermoplastic Insulated Wires and Cables\u003c\/li\u003e\n\u003cli\u003eUL 758 Standard for Appliance Wiring Material\u003c\/li\u003e\n\u003cli\u003eUL 1063 Machine Tool Wiring (MTW)\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 75 Thermoplastic Insulated Wires and Cables\u003c\/li\u003e\n\u003cli\u003eICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003c\/li\u003e\n\u003cli\u003eFederal Specification A-A-59544\u003c\/li\u003e\n\u003cli\u003eNMX-J-010-ANCE Thermoplastic insulated wires and cables\u003c\/li\u003e\n\u003cli\u003eNOM-063-SCFI Electrical Products – Conductors – Safety Requirements\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eApplication \u0026amp; Features\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSouthwire THHN copper conductors are primarily used in conduit for branch circuits in commercial or industrial applications as specified in the National Electrical Code® and other applicable codes and standards. Voltage for all applications is 600 volts. These conductors have multiple ratings depending upon the product application.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Allowable temperatures are as follows:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTHHN or T90 Nylon- Dry locations not to exceed 90°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTHWN- Wet locations not to exceed 75°C or dry locations not to exceed 90°C or locations not to exceed 75°C when exposed to oil\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTWN75- Wet locations not to exceed 75°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMTW- Wet locations or when exposed to oil at temperatures not to exceed 60°C or dry locations not to exceed 90°C (with ampacity limited to that for 75°C conductor temperature per NFPA 79)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAWM- Dry locations not to exceed 105°C only when rated and used as appliance wiring material\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eGasoline and Oil Resistant II\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVW-1 Sizes 14 through 10 AWG\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFT1 All SizesAWM- Sizes 14 through 10 AWG\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMTW- Stranded Constructions Only\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRoHS Compliant\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Southwire","offers":[{"title":"500 ft Red","offer_id":51162563477785,"sku":"513531","price":1.19,"currency_code":"USD","in_stock":true},{"title":"500 ft Black","offer_id":50822044090649,"sku":"513515","price":1.19,"currency_code":"USD","in_stock":true},{"title":"500' Black","offer_id":50829051101465,"sku":"513515","price":1.19,"currency_code":"USD","in_stock":true},{"title":"500 ft White","offer_id":50806954164505,"sku":"513523","price":1.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-446361.png?v=1781028404"},{"product_id":"southwire-14-19-sd-cu-thhn-thwn-mtw-awm-ul-cul","title":"Southwire  14-19 SD CU THHN-THWN-MTW-AWM UL\/c(UL)","description":"\u003ch3 class=\"tab-panel__heading\"\u003eConstruction\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cul\u003e\n\u003cli\u003eConductor: Solid sizes #14 AWG - #10 AWG use soft drawn bare copper per ASTM B3. Stranded sizes #14 AWG - #10 AWG use a combination-unilay stranded soft drawn bare copper per ASTM B787.\u003c\/li\u003e\n\u003cli\u003eInsulation: Heat and moisture resistant PVC\u003c\/li\u003e\n\u003cli\u003eSheath: Nylon\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eStandards \u0026amp; References\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cul\u003e\n\u003cli\u003eASTM B3 Soft or Annealed Copper Wire\u003c\/li\u003e\n\u003cli\u003eASTM B787 19 Wire Combination Unilay-Stranded Copper Conductors\u003c\/li\u003e\n\u003cli\u003eUL 83 Thermoplastic Insulated Wires and Cables\u003c\/li\u003e\n\u003cli\u003eUL 758 Standard for Appliance Wiring Material\u003c\/li\u003e\n\u003cli\u003eUL 1063 Machine Tool Wiring (MTW)\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 75 Thermoplastic Insulated Wires and Cables\u003c\/li\u003e\n\u003cli\u003eICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003c\/li\u003e\n\u003cli\u003eFederal Specification A-A-59544\u003c\/li\u003e\n\u003cli\u003eNMX-J-010-ANCE Thermoplastic insulated wires and cables\u003c\/li\u003e\n\u003cli\u003eNOM-063-SCFI Electrical Products – Conductors – Safety Requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eApplication \u0026amp; Features\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSouthwire THHN copper conductors are primarily used in conduit for branch circuits in commercial or industrial applications as specified in the National Electrical Code® and other applicable codes and standards. Voltage for all applications is 600 volts. These conductors have multiple ratings depending upon the product application.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Allowable temperatures are as follows:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTHHN or T90 Nylon- Dry locations not to exceed 90°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTHWN- Wet locations not to exceed 75°C or dry locations not to exceed 90°C or locations not to exceed 75°C when exposed to oil\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTWN75- Wet locations not to exceed 75°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMTW- Wet locations or when exposed to oil at temperatures not to exceed 60°C or dry locations not to exceed 90°C (with ampacity limited to that for 75°C conductor temperature per NFPA 79)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAWM- Dry locations not to exceed 105°C only when rated and used as appliance wiring material\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e Gasoline and Oil Resistant II\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVW-1 Sizes 14 through 10 AWG\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFT1 All Sizes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAWM- Sizes 14 through 10 AWG\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMTW- Stranded Constructions Only\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRoHS Compliant\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Southwire","offers":[{"title":"500 ft Green","offer_id":50806954230041,"sku":"602409","price":0.65,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-446360.png?v=1780324564"},{"product_id":"cerrowire-cerromax-uf-b-underground-feeder-branch-cable-with-nonmetallic-sheath","title":"CerroWire CerroMax™ UF-B Underground Feeder\/Branch Cable with Nonmetallic Sheath","description":"\u003ch3 class=\"et_pb_toggle_title\"\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eFor use underground as a feeder or branch circuit cable where provided with overcurrent protection of the rated ampacity as specified by the NEC\u003csup\u003e®\u003c\/sup\u003e. Direct burial in the earth is permitted. May be installed as interior wiring in wet, dry, or corrosive locations as specified by the NEC May be installed as nonmetallic-sheathed cable as specified in NEC Section 340.10(4). May be installed in locations with temperatures up to 90°C but with the ampacity limited to that of 60°C conductors.\u003c\/p\u003e\n\u003ch3 class=\"et_pb_toggle_title\"\u003eConductors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSolid conductors\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eSoft, uncoated copper per ASTM-B3\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStranded conductors\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eUncoated copper per ASTM-B3 and ASTM-B\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGrounded Conductors\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eSoft, uncoated copper per ASTM-B3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"et_pb_toggle_title\"\u003eInsulation\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eColor-coded PVC (polyvinyl chloride) rated 90°C dry with nylon (polyamide) covering.\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"small_caps\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cimg\u003e\u003c\/p\u003e\n\u003ch3 class=\"et_pb_toggle_title\"\u003eJacket\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eGray PVC (polyvinyl chloride) jacket applied over and around the insulated and bare conductors\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"et_pb_toggle_title\"\u003eIndustry Standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL 83: E15119\u003c\/li\u003e\n\u003cli\u003eUL 493: E26403\u003c\/li\u003e\n\u003cli\u003eASTM B3\u003c\/li\u003e\n\u003cli\u003eASTM B8\u003c\/li\u003e\n\u003cli\u003eFederal Specification A-A-59544\u003c\/li\u003e\n\u003cli\u003eNFPA70: National Electrical Code\u003csup\u003e®\u003c\/sup\u003e\u003cbr\u003eRoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*It is the sole responsibility of the end user to determine suitability of this product for its intended end use and application.\u003c\/p\u003e\n\u003ch3 class=\"et_pb_toggle_title\"\u003eAssembly\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eInsulated conductors are laid parallel with a bare grounding conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!----\u003e","brand":"Cerrowire","offers":[{"title":"25 ft.","offer_id":50806954852633,"sku":"853143","price":52.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-446290.png?v=1780324569"},{"product_id":"copy-of-marmon-home-improvement-125-ft-6-2-black-stranded-cerromax-slipwire-copper-nm-b-wire","title":"Marmon Home Improvement 125 ft. 6\/2 Black Stranded CerroMax SLiPWire Copper NM-B Wire","description":"\u003cp\u003eFor use primarily in residential wiring, including branch circuits for outlets, switches, etc.\u003cbr\u003e\u003cbr\u003eMay be installed in both exposed and concealed work in normally dry locations. May be installed in air voids of masonry block or tile walls where these walls are not subject to excessive moisture or dampness. May be installed in locations with temperatures up to 90°C, but with the ampacity limited to that of 60°C conductors. Added Circuit: For use primarily in residential wiring for branch circuits supplying outlets located in bedrooms and other areas. Has two separated neutrals so one cable can be used to run two circuits when sharing of a neutral is not allowed.\u003c\/p\u003e\n\u003cp\u003eBranch circuit wiring\u003cbr\u003eCeiling fans\u003cbr\u003eDry locations only\u003cbr\u003eReceptacles\u003cbr\u003eResidential\u003c\/p\u003e","brand":"Marmon Home Improvement","offers":[{"title":"125' \/ Black","offer_id":50926187184409,"sku":"434514","price":4.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-329408.jpg?v=1780324204"},{"product_id":"southwire-romex-brand-simpull-copper-type-nm-b-cable","title":"Southwire Romex® Brand SIMpull® Copper Type NM-B Cable","description":"\u003cp class=\"info-panel__description\"\u003eNonmetallic-Sheathed Cable. 600 Volt. Copper Conductor. PVC Insulation\/Nylon Sheath. PVC Jacket with SIMpull\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eTechnology for Easier Pulling.\u003c\/p\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eConstruction\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cul\u003e\n\u003cli\u003eConductor: Bare copper per ASTM B3. Sizes #14 AWG - #10 AWG are solid. Sizes #8 AWG - #2 AWG are Class B compressed stranded per ASTM B8\u003c\/li\u003e\n\u003cli\u003eInsulation: All phases and neutral(s) are insulated with Polyvinyl Chloride (PVC) with Nylon Sheath 2\/C: Black, White 3\/C: Black, Red, White 4\/C: Black, Red, Blue, White\u003c\/li\u003e\n\u003cli\u003eGround: Solid soft drawn bare copper with kraft paper wrap\u003c\/li\u003e\n\u003cli\u003eBinder: Kraft paper\u003c\/li\u003e\n\u003cli\u003eJacket: Polyvinyl Chloride (PVC) jacket utilizing SIMpull Technology\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eStandards \u0026amp; References\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cul\u003e\n\u003cli\u003eASTM B3 Soft or Annealed Copper Wire\u003c\/li\u003e\n\u003cli\u003eASTM B8 Concentric-Lay-Stranded Copper Conductors\u003c\/li\u003e\n\u003cli\u003eUL 719 Nonmetallic-Sheathed Cables\u003c\/li\u003e\n\u003cli\u003eRoHS-2 (European Directive 2011\/65\/EU)\u003c\/li\u003e\n\u003cli\u003eFederal Specification A-A-59544\u003c\/li\u003e\n\u003cli\u003eNOM-063-SCFI Electrical Products – Conductors – Safety Requirements\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eApplication \u0026amp; Features\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cp\u003e\u003cspan\u003eSouthwire Romex\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e Brand SIMpull\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e Type NM-B (nonmetallic-sheathed) cable may be used for both exposed and concealed work in dry locations as specified in the National Electrical Code®. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B cable is 600 volts.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Southwire","offers":[{"title":"10\/3 x 25 ft","offer_id":50938820591897,"sku":"853168","price":129.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-445310.png?v=1780324443"},{"product_id":"southwire-solid-building-wire-14-sol-sd-cu-thhn-thwn-awm","title":"Southwire Solid Building Wire 14 SOL SD CU THHN-THWN-AWM","description":"\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e \u003c\/p\u003e\u003col\u003e\n\u003cli\u003eConductor: Solid sizes #14 AWG - #10 AWG use soft drawn bare copper per ASTM B3. Stranded sizes #14 AWG - #10 AWG use a combination-unilay stranded soft drawn bare copper per ASTM B787.\u003c\/li\u003e\n\u003cli\u003eInsulation: Heat and moisture resistant PVC\u003c\/li\u003e\n\u003cli\u003eSheath: Nylon\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplication \u0026amp; Features\u003c\/strong\u003e \u003c\/p\u003e\u003cp\u003eAPPLICATION\u003cbr\u003eSouthwire THHN copper conductors are primarily used in conduit for branch circuits in commercial or industrial applications as specified in the National Electrical Code® and other applicable codes and standards. Voltage for all applications is 600 volts. These conductors have multiple ratings depending upon the product application. Allowable temperatures are as follows:\u003cbr\u003e- THHN or T90 Nylon- Dry locations not to exceed 90°C\u003cbr\u003e- THWN- Wet locations not to exceed 75°C or dry locations not to exceed 90°C or locations not to exceed 75°C when exposed to oil\u003cbr\u003e- TWN75- Wet locations not to exceed 75°C\u003cbr\u003e- MTW- Wet locations or when exposed to oil at temperatures not to exceed 60°C or dry locations not to exceed 90°C (with ampacity limited to that for 75°C conductor temperature per NFPA 79)\u003cbr\u003e- AWM- Dry locations not to exceed 105°C only when rated and used as appliance wiring material\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003cbr\u003e- Gasoline and Oil Resistant II\u003cbr\u003e- VW-1 Sizes 14 through 10 AWG\u003cbr\u003e- FT1 All Sizes\u003cbr\u003e- AWM- Sizes 14 through 10 AWG\u003cbr\u003e- MTW- Stranded Constructions Only\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e","brand":"Southwire","offers":[{"title":"Black \/ 500'","offer_id":51209567207705,"sku":"513465","price":0.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-407177.jpg?v=1780324514"},{"product_id":"southwire-solid-building-wire-12-sol-sd-cu-thhn-thwn-awm","title":"Southwire Solid Building Wire 12 SOL SD CU THHN-THWN-AWM","description":"\u003cp\u003eConstruction \u003c\/p\u003e\u003col\u003e\n\u003cli\u003eConductor: Solid sizes #14 AWG - #10 AWG use soft drawn bare copper per ASTM B3. Stranded sizes #14 AWG - #10 AWG use a combination-unilay stranded soft drawn bare copper per ASTM B787.\u003c\/li\u003e\n\u003cli\u003eInsulation: Heat and moisture resistant PVC\u003c\/li\u003e\n\u003cli\u003eSheath: Nylon\u003c\/li\u003e\n\u003c\/ol\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplication \u0026amp; Features\u003c\/strong\u003e \u003c\/p\u003e\u003cp\u003eAPPLICATION\u003cbr\u003eSouthwire THHN copper conductors are primarily used in conduit for branch circuits in commercial or industrial applications as specified in the National Electrical Code® and other applicable codes and standards. Voltage for all applications is 600 volts. These conductors have multiple ratings depending upon the product application. Allowable temperatures are as follows:\u003cbr\u003e- THHN or T90 Nylon- Dry locations not to exceed 90°C\u003cbr\u003e- THWN- Wet locations not to exceed 75°C or dry locations not to exceed 90°C or locations not to exceed 75°C when exposed to oil\u003cbr\u003e- TWN75- Wet locations not to exceed 75°C\u003cbr\u003e- MTW- Wet locations or when exposed to oil at temperatures not to exceed 60°C or dry locations not to exceed 90°C (with ampacity limited to that for 75°C conductor temperature per NFPA 79)\u003cbr\u003e- AWM- Dry locations not to exceed 105°C only when rated and used as appliance wiring material\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003cbr\u003e- Gasoline and Oil Resistant II\u003cbr\u003e- VW-1 Sizes 14 through 10 AWG\u003cbr\u003e- FT1 All Sizes\u003cbr\u003e- AWM- Sizes 14 through 10 AWG\u003cbr\u003e- MTW- Stranded Constructions Only\u003cbr\u003e- RoHS Compliant\u003c\/p\u003e","brand":"Southwire","offers":[{"title":"Green \/ 500'","offer_id":51209567174937,"sku":"513556","price":1.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-407182.jpg?v=1780324514"},{"product_id":"cerrowire-thhnthwn-2-copper-wire","title":"Cerrowire THHN\/THWN-2 Copper Wire","description":"\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThermoplastic-insulated copper wire with a nylon covering. Sizes 8 AWG through 1000 kcmil feature Cerrowire SLiPWire® Technology for fast and easy pulling in conduit. This 90°C, 600 volt building wire is for use in residential, commercial and industrial applications. Intended for use in accordance with the National Electrical Code® in both wet and dry locations. Conductors 14 AWG through 1 AWG are marked VW-1 and 1\/0 AWG through 1000 kcmil are rated for use in cable tray. When used as appliance wire, 105°C dry rated.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAdditional Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGasoline and Oil Resistant II\u003c\/li\u003e\n\u003cli\u003eMachine Tool Wire: 90°C Dry\u003c\/li\u003e\n\u003cli\u003eAppliance Wire: 105°C Dry\u003c\/li\u003e\n\u003cli\u003eRated THHN\/THWN-2: 90°C Dry or Wet\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSolid conductors\u003c\/strong\u003e \u003c\/p\u003e\u003cp\u003eSoft, uncoated copper per ASTM B3\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eStranded conductors\u003c\/strong\u003e \u003c\/p\u003e\u003cp\u003eUncoated copper per ASTM B3, B8, and B787\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eNylon (polyamide) color-coded THHN\/THWN-2. Sizes 8 AWG through 1000 kcmil SLiPWire® are self-lubricated with CERROWIRE’s Self-Lubricating Polymer Technology. Sizes 1 AWG and larger are available printed with True Sequential Footage™ on master reels.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eColors\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eBlack\u003c\/p\u003e\u003cp\u003eWhite\u003c\/p\u003e\u003cp\u003eRed\u003c\/p\u003e\u003cp\u003eOrange\u003c\/p\u003e\u003cp\u003eYellow\u003c\/p\u003e\u003cp\u003eGreen\u003c\/p\u003e\u003cp\u003eBlue\u003c\/p\u003e\u003cp\u003ePurple\u003c\/p\u003e\u003cp\u003eBrown\u003c\/p\u003e\u003cp\u003eGrey\u003c\/p\u003e\u003cp\u003ePink\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Cerrowire","offers":[{"title":"White \/ 500'","offer_id":52055233528089,"sku":"513473","price":0.19,"currency_code":"USD","in_stock":true},{"title":"Green \/ 500'","offer_id":51695400419609,"sku":"513507","price":0.7,"currency_code":"USD","in_stock":true},{"title":"Red \/ 500'","offer_id":52020412809497,"sku":"513531","price":1.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-461912.png?v=1781028418"},{"product_id":"southwire-14-19-sd-cu-thhn-thwn-mtw-awm-ulcul-red-500-ft","title":"Southwire 14-19 SD CU THHN-THWN-MTW-AWM UL\/c(UL) RED 500 FT","description":"\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eConductor: Solid sizes #14 AWG - #10 AWG use soft drawn bare copper per ASTM B3. Stranded sizes #14 AWG - #10 AWG use a combination-unilay stranded soft drawn bare copper per ASTM B787.\u003c\/li\u003e\n\u003cli\u003eInsulation: Heat and moisture resistant PVC\u003c\/li\u003e\n\u003cli\u003eSheath: Nylon\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eStandards \u0026amp; References\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eASTM B3 Soft or Annealed Copper Wire\u003c\/li\u003e\n\u003cli\u003eASTM B787 19 Wire Combination Unilay-Stranded Copper Conductors\u003c\/li\u003e\n\u003cli\u003eUL 83 Thermoplastic Insulated Wires and Cables\u003c\/li\u003e\n\u003cli\u003eUL 758 Standard for Appliance Wiring Material\u003c\/li\u003e\n\u003cli\u003eUL 1063 Machine Tool Wiring (MTW)\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 75 Thermoplastic Insulated Wires and Cables\u003c\/li\u003e\n\u003cli\u003eICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003c\/li\u003e\n\u003cli\u003eFederal Specification A-A-59544\u003c\/li\u003e\n\u003cli\u003eNMX-J-010-ANCE Thermoplastic insulated wires and cables\u003c\/li\u003e\n\u003cli\u003eNOM-063-SCFI Electrical Products – Conductors – Safety Requirements\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplication \u0026amp; Features\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAPPLICATION\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSouthwire THHN copper conductors are primarily used in conduit for branch circuits in commercial or industrial applications as specified in the National Electrical Code® and other applicable codes and standards. Voltage for all applications is 600 volts. These conductors have multiple ratings depending upon the product application.\u003c\/p\u003e\u003cp\u003eAllowable temperatures are as follows:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTHHN or T90 Nylon- Dry locations not to exceed 90°C\u003c\/li\u003e\n\u003cli\u003eTHWN- Wet locations not to exceed 75°C or dry locations not to exceed 90°C or locations not to exceed 75°C when exposed to oil\u003c\/li\u003e\n\u003cli\u003eTWN75- Wet locations not to exceed 75°C\u003c\/li\u003e\n\u003cli\u003eMTW- Wet locations or when exposed to oil at temperatures not to exceed 60°C or dry locations not to exceed 90°C (with ampacity limited to that for 75°C conductor temperature per NFPA 79)\u003c\/li\u003e\n\u003cli\u003eAWM- Dry locations not to exceed 105°C only when rated and used as appliance wiring material\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGasoline and Oil Resistant II\u003c\/li\u003e\n\u003cli\u003eVW-1 Sizes 14 through 10 AWG\u003c\/li\u003e\n\u003cli\u003eFT1 All Sizes\u003c\/li\u003e\n\u003cli\u003eAWM- Sizes 14 through 10 AWG\u003c\/li\u003e\n\u003cli\u003eMTW- Stranded Constructions Only\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Southwire","offers":[{"title":"500 ft. \/ Red","offer_id":51728509927705,"sku":"602383","price":0.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-462967.png?v=1780324448"},{"product_id":"southwire-romex-brand-simpull-type-nm-b-cable-10-3","title":"Southwire Romex® Brand SIMpull® Type NM-B Cable 10-3","description":"\u003cp class=\"info-panel__description\"\u003eNonmetallic-Sheathed Cable. 600 Volt. Copper Conductors. Color-Coded Jacket. SIMpull® Jacket Designed for Easier Pulling.\u003c\/p\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eApplication\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cp\u003eSouthwire® Romex ® Brand SIMpull® NM-B (nonmetallic-sheathed) cable may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified in the National Electrical Code. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B cable is 600 volts.\u003c\/p\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eStandards \u0026amp; References\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cp\u003eSouthwire Romex® Brand SIMpull® NM-B cable complies with the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eListed per UL Standard 719\u003c\/li\u003e\n\u003cli\u003eUL 83 (Conductor Construction)\u003c\/li\u003e\n\u003cli\u003eASTM B-3 and B-8\u003c\/li\u003e\n\u003cli\u003eFederal Specification A-A-59544\u003c\/li\u003e\n\u003cli\u003eNational Electrical Code, NFPA 70\u003c\/li\u003e\n\u003cli\u003eREACH\/RoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"tab-panel__heading\"\u003eConstruction\u003c\/h3\u003e\n\u003cdiv class=\"tab-panel__content tab-panel__content--skinny\"\u003e\n\u003cp\u003e\u003cspan\u003eSouthwire Romex® Brand SIMpull® NM-B cable is manufactured as 2, 3, or 4 conductor cable, with a bare ground wire. Copper conductors are annealed (soft)copper. Stranded conductors are compressed stranded. Conductor insulation is 90°C-rated polyvinyl chloride (PVC), nylon jacketed. Romex® Brand SIMpull® NM-B cable is designed for easier pulling, resulting in easier installation. The cable jacket is color-coded for quick size identification; White - 14 AWG, Yellow - 12 AWG, Orange - 10 AWG, and Black - 8 AWG and 6 AWG.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Southwire","offers":[{"title":"100'","offer_id":51731019956505,"sku":"163444","price":299.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-375378.jpg?v=1780324451"},{"product_id":"southwire-14-19-sd-cu-thhn-thwn-mtw-awm-ulcul-white-500-ft","title":"Southwire 14-19 SD CU THHN-THWN-MTW-AWM UL\/c(UL) WHITE 500 FT","description":"\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eConductor: Solid sizes #14 AWG - #10 AWG use soft drawn annealed bare copper per ASTM B3. Stranded sizes #14 AWG - #10 AWG use Class C combination-unilay soft drawn annealed bare copper per ASTM B787.\u003c\/li\u003e\n\u003cli\u003eInsulation: Heat and moisture resistant PVC\u003c\/li\u003e\n\u003cli\u003eSheath: Nylon\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eStandards \u0026amp; References\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eASTM B3 Soft or Annealed Copper Wire\u003c\/li\u003e\n\u003cli\u003eASTM B787 19 Wire Combination Unilay-Stranded Copper Conductors\u003c\/li\u003e\n\u003cli\u003eUL 83 Thermoplastic Insulated Wires and Cables\u003c\/li\u003e\n\u003cli\u003eUL 758 Standard for Appliance Wiring Material\u003c\/li\u003e\n\u003cli\u003eUL 1063 Machine Tool Wiring (MTW)\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 75 Thermoplastic Insulated Wires and Cables\u003c\/li\u003e\n\u003cli\u003eICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy\u003c\/li\u003e\n\u003cli\u003eFederal Specification A-A-59544\u003c\/li\u003e\n\u003cli\u003eNMX-J-010-ANCE Thermoplastic insulated wires and cables\u003c\/li\u003e\n\u003cli\u003eNOM-063-SCFI Electrical Products – Conductors – Safety Requirements\u003c\/li\u003e\n\u003cli\u003eNEMA 70901-2-2024 Make It American Compliance with Domestic Preference Requirements Pt. 2 Wire \u0026amp; Cable\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplication \u0026amp; Features\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003eAPPLICATIONSouthwire THHN copper conductors are primarily used in conduit for branch circuits in commercial or industrial applications as specified in the National Electrical Code® and other applicable codes and standards. Voltage for all applications is 600 volts. These conductors have multiple ratings depending upon the product application. Allowable temperatures are as follows:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTHHN or T90 Nylon- Dry locations not to exceed 90°C\u003c\/li\u003e\n\u003cli\u003eTHWN- Wet locations not to exceed 75°C or dry locations not to exceed 90°C or locations not to exceed 75°C when exposed to oil\u003c\/li\u003e\n\u003cli\u003eTWN75- Wet locations not to exceed 75°C\u003c\/li\u003e\n\u003cli\u003eMTW- Wet locations or when exposed to oil at temperatures not to exceed 60°C or dry locations not to exceed 90°C (with ampacity limited to that for 75°C conductor temperature per NFPA 79)\u003c\/li\u003e\n\u003cli\u003eAWM- Dry locations not to exceed 105°C only when rated and used as appliance wiring material\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGasoline and Oil Resistant II\u003c\/li\u003e\n\u003cli\u003eVW-1 Sizes 14 through 10 AWG\u003c\/li\u003e\n\u003cli\u003eFT1 All Sizes\u003c\/li\u003e\n\u003cli\u003eAWM- Sizes 14 through 10 AWG\u003c\/li\u003e\n\u003cli\u003eMTW- Stranded Constructions Only\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Southwire","offers":[{"title":"White","offer_id":51887717712153,"sku":"602375","price":0.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-467776.png?v=1780324480"},{"product_id":"klein-tools-test-kit-with-multimeter-non-contact-volt-tester-receptacle-tester","title":"Klein Tools Test Kit with Multimeter Non-Contact Volt Tester Receptacle Tester","description":"\u003cul\u003e\n\u003cli\u003eMultimeter measures up to 600V AC\/DC voltage, 10A DC current and 2MOhms resistance\u003c\/li\u003e\n\u003cli\u003eNon-Contact Voltage Tester Cat. No. NCVT1XT has a bright green LED to indicate the tester is working; it changes to red and audible tones sound when voltage is detected\u003c\/li\u003e\n\u003cli\u003eNCVT1XT has a high intensity, bright red LED that illuminates and an audible tone when voltage is detected from 50 to 1000 VAC power operating range\u003c\/li\u003e\n\u003cli\u003eReceptacle tester Cat. No. RT110 detects wiring configurations and indicates correct wiring, and identifies common wiring faults\u003c\/li\u003e\n\u003cli\u003eIdentifies open ground, open hot, open neutral, hot\/ground reversed; it does not indicate quality of ground, multiple hot wires, or a combination of defects\u003c\/li\u003e\n\u003cli\u003eMM320 multimeter tests continuity with visual and audible continuity indicators\u003c\/li\u003e\n\u003cli\u003eTest leads included for Cat. No. MM320; batteries included for Cat. Nos. NCVT1XT and MM320\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003eKlein Tools Multimeter Test Kit contains Cat. No. MM320 (Digital Multimeter), Cat. No. NCVT1XT (Non-Contact Voltage Tester) and Cat. No. RT110 (Receptacle Tester). The MM320 measures DC current, AC\/DC voltage and resistance. The NCVT1XT automatically detects standard voltage in cables, cords, circuit breakers, lighting fixtures, switches, outlets, and wires. The RT110 detects the most common wiring problems in standard receptacles.\u003c\/p\u003e","brand":"Klein Tools","offers":[{"title":"600V 10A 2M","offer_id":52186590740761,"sku":"270876","price":54.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-475943.jpg?v=1781028407"},{"product_id":"marmon-home-improvement-500-ft-white-8-stranded-building-wire-112-4002j","title":"Marmon Home Improvement 500-ft. White 8 Stranded Building Wire 112-4002j","description":"\u003cp\u003eThermoplastic-insulated copper wire with a nylon covering. Sizes 8 AWG through 1000 kcmil feature Cerrowire SLiPWire® Technology for fast and easy pulling in conduit. This 90°C, 600 volt building wire is for use in residential, commercial and industrial applications. Intended for use in accordance with the National Electrical Code® in both wet and dry locations. Conductors 14 AWG through 1 AWG are marked VW-1 and 1\/0 AWG through 1000 kcmil are rated for use in cable tray. When used as appliance wire, 105°C dry rated.\u003c\/p\u003e","brand":"Marmon Home Improvement","offers":[{"title":"500' \/ White","offer_id":52249951502617,"sku":"667501","price":1.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-478717_0c8b59ee-7836-4248-802e-9f0b6208180a.jpg?v=1781028417"},{"product_id":"southwire-14-3sol-lite-whip-3-8-fmc-rws-6-black-white-green-lock-nut-15-ea","title":"Southwire 14-3SOL Lite-Whip 3\/8\"FMC-RWS 6' Black\/White\/Green Lock-Nut 15 EA","description":"\u003cul\u003e\n\u003cli\u003eConductor:Class B compressed stranded copper per ASTM B3 and ASTM B8\u003c\/li\u003e\n\u003cli\u003eInsulation:All phases are insulated with Polyvinyl Chloride with Nylon Sheath Type THHN\/THWN\u003c\/li\u003e\n\u003cli\u003eGround: Green insulated copper ground\u003c\/li\u003e\n\u003cli\u003eBinder:Binder tape bearing the print legend is wrapped around the cable assembly\u003c\/li\u003e\n\u003cli\u003eConnector:Zinc die-cast locknut or snap-in connector\u003c\/li\u003e\n\u003cli\u003eArmor:Steel Interlocked Armor\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eStandards \u0026amp; References\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eASTM B8 Concentric-Lay-Stranded Copper Conductors\u003c\/li\u003e\n\u003cli\u003eUL 83 Thermoplastic Insulated Wires and Cables\u003c\/li\u003e\n\u003cli\u003eUL 1569 Metal-Clad Cables\u003c\/li\u003e\n\u003cli\u003eUL 1479 Standard for Safety Fire Tests of Penetration Firestops\u003c\/li\u003e\n\u003cli\u003eUL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test\u003c\/li\u003e\n\u003cli\u003eBuy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplication \u0026amp; Features\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSouthwire EZ QUICK™ Modular Cable Assemblies are suitable for use as follows:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBranch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.\u003c\/li\u003e\n\u003cli\u003eFished or embedded in plaster.\u003c\/li\u003e\n\u003cli\u003eConcealed or exposed installations.\u003c\/li\u003e\n\u003cli\u003eEnvironmental air-handling spaces per NEC 300.22 (C).\u003c\/li\u003e\n\u003cli\u003ePlaces of Assembly per NEC 518.4 and theaters per NEC 520.5.\u003c\/li\u003e\n\u003cli\u003eInstallation in cable tray and approved raceways.\u003c\/li\u003e\n\u003cli\u003eUnder raised floors for information technology equipment conductors and cables per NEC 645.5(D) \u0026amp; 645.5(D)(2)\u003c\/li\u003e\n\u003cli\u003eClass I Div. 2, Class II Div 2, \u0026amp; Class III Div. 1 Hazardous Locations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSouthwire EZ QUICK™ Modular Cable Assemblies - meets or exceeds the following requirements:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )\u003c\/li\u003e\n\u003cli\u003eFederal Specification A-A59544 (formerly J-C-30B)\u003c\/li\u003e\n\u003cli\u003eNFPA 70 (National Electrical Code), Article 330\u003c\/li\u003e\n\u003cli\u003eListed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems\u003c\/li\u003e\n\u003cli\u003eREACH\/RoHS-2 (Chemical Limit) Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSouthwire EZ QUICK™ Modular Cable Assemblies Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReduces installation costs up to 50% over pipe and wire.\u003c\/li\u003e\n\u003cli\u003eLightweight aluminum armor--as much as 45% lighter than steel MC Cable.\u003c\/li\u003e\n\u003cli\u003eBetter grounding performance than Type AC\u003c\/li\u003e\n\u003cli\u003ePre-cut lengths eliminate on-site preparation and save installation and clean up time.\u003c\/li\u003e\n\u003cli\u003ePre-stripped conductors increase jobsite safety\u003c\/li\u003e\n\u003cli\u003eUL Listed snap-in fittings applied to each end\u003c\/li\u003e\n\u003cli\u003eUL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038.\u003c\/li\u003e\n\u003cli\u003eCable reverse wound on reel for ease of pulling and installation. When pulling from coils, pull from inside to ensure ease of installation.\u003c\/li\u003e\n\u003cli\u003eAnti-short bushings are not required for use with MC cable per the NEC and UL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Southwire","offers":[{"title":"3\/8\" x 6'","offer_id":52480692224281,"sku":"567477","price":23.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/9091\/2281\/files\/product-media-483694.png?v=1780650097"}],"url":"https:\/\/mmhardwarerental.com\/collections\/electrical-electrical-wiring.oembed?page=2","provider":"M\u0026M True Value Hardware","version":"1.0","type":"link"}